Screw the head down onto the resin tank until solid contact is made between the tank and O-ring, then tighten about another 1/4–1/3 of a turn and STOP. Hold Extra Cycle and Down buttons for 25 seconds. Metered (Flow) Immediate - will backwash immediately after programmed capacity is reached. Allow water to run out of the faucet until no more air comes out, then close the faucet. Typical backwash process takes roughly 30-40 minutes. Sometimes the same media will be packaged in different bags, this is not uncommon. Systems with the Vortech tank will typically not require gravel, though some heavier media and larger systems will still use it. If not 100% positive, you can slightly open the water supply after cutting into the pipe to determine where the water is coming from so the system can be connected correctly. These systems can be ran to your sewer or septic line and is typically the recommended place to run the drain. --After filling the tank above the media level, you can blow into the riser tuber (or use an air compressor) to create air around the riser tube allwoing you to gently push it back down into position. Electrical Facilities An uninterrupted alternating current (A/C) supply is required. Valve Body 2510 PN 19328 IN STOCK Your Price: $59.95 . It is manufactured by one of the world’s largest water treatment companies. If hiring a plumber ensure they have a copy before they start. A physical air gap of at least 3 inches (76 mm) between the end of the drain line and the wastewater level in the drain pipe should be used to avoid contamination of the line. Resin - Used in softeners - Small beads, similar to wet sand, various colors System installation requires information from a number of Open a nearby COLD faucet and check to ensure there are no leaks that show up when water is running. 2. Unplug the system and check to ensure all electrical connections and cam switches are secure. Check the system for any leaks, paying attention to the seal between the tank and control head as well as the connections between the bypass valve and control head. Plug the control head into a qualifying outlet as stated in the requirements section. If you have a lot of sand in the water a spin down filter (part #SDF-100) is recommended to protect the control head - http://store.afwfilters.com/parts-components/spin-down-sand-separator-filter-1-inch/. From the back (see Fig 2) the water enters on the left. If you do have one the larger end will fit inside the bottom of your control valve, with the smaller end sliding over the riser tube pointing down into the tank (). The integrated Fleck SXT digital 2510 Meter based water softeners are used when you want to regenerate your softener based on the amount of water you use. The manufacturer reserves the right to make changes at any time without notice. Metered (Flow) Delayed - will backwash at the preset time after programmed capacity is reached. Basic plumbing skills are required for installation. Fleck 2510 Meter Cap Extended Range 90 Degree Right Angle 15659 $165.00 Meter Assy, 3/4-inch Dual Port, Slip Std, RT Angle/180 Plastic Paddle Wheel, w/clips 60088-180 60089-180 If you are unsure what you have feel free to contact us to ensure you place the media in the correct tank. This Product Includes: Fleck 2510 Meter Valve & Cover; Plumbing Adapter (As Chosen From Options) These settings typically use the default values and should not need adjusted. The Fleck 2510 12 Day Timer control valve has a mechanical meter that regulates the regeneration time based on the number of gallons you have chosen. Slowly open up the bypass valve just to the point of allowing water to enter the system at a trickle, and leave it like that until the tank is full of water. Parameter Display - During programming, indicates which setting you are on. GFCI outlet is recommended. Autotrol LOGIX 255/740 Electronic Timeclock. After pushing the bypass and control valve together, tighten the screws to secure the clips and hold everything in place. Verify they are present and free from nicks or kinks. Sets backwash frequency. Most systems with Vortech tanks do NOT use gravel, though heavier medias used for iron will. That is the flow icon. We are committed to providing the best customer experience possible and have provided these installation instructions to make things as simple as possible. Copyright © 2020 Quality Water For Less. Then press BOTH the UP and DOWN buttons at the same time and hold for 5-10 seconds until the Parameter Display shows DF. You will supply the required fittings to connect from the system to your plumbing, this will typically consist of threaded adapters that will connect directly to the bypass/yoke, fittings to tie into your main line, and the copper/PVC/PEX line to connect between them. NOTE: Other voltages are available. After reconnecting the piston, inspect the control head for any broken, worn, or disconnected parts, and replace or reconnect any that are found. Includes O-rings (already attached) to seal the connection and screws and clips to secure the connection. Screws on top of the tank and controls the water flow and backwashing cycles. It is NOT an error code, if there is an error the error icon will be displayed and the error code will be the only thing displayed. The Fleck 2510 brand control heads help make these water softeners long lasting and trouble free. Whole house cartridge systems are typically installed after any tank systems, the Scale Sentry system after the cartridge system(s), and any UV systems will be last. Flow Indicator - Only active on metered softeners. This sets the length of the brine fill portion of the cycle. Once properly tightened down check to ensure the tank and control head meet evenly all the way around. If the valve came with a separate electronic timer service manual, refer to the timer operation section of the electronic timer service manual. Do not overtighten the screws to avoid damage. If you do not have one then it is not needed. Most questions that arise are answered in this manual or the FAQ section at the end. To have it run at a different time (for example if you work late and are up and using water at the default time) you will need to adjust the current time of day to trick the system into doing so at the desired time. See end of programming section for error code explainations. During normal operation alternates between current time and days until the next backwash. AFWFilters Fleck 2510 Filter only head replacement backwashing valve, Black. If you have the Vortech tank it replaces the standard tank, and the riser is not removable After verifying programming run the system through a backwash and watch the motor to ensure that it is moving the piston, if it is not the motor needs to be replaced. This sets the time that the backwash cycle will start. Filox/Mang-Ox - Used in stand alone system and Air Injection Platinum system -Heavy, dark media that looks like finely crushed rock It is seated very securely up inside the pilot hole, inside a groove, so it can be hard to see. The display should light up and start flashing a time. It is VERY unlikely that the pilot O-ring is missing. Depending on system configuration your system may include a top distributor basket (). KDF Media - Additive on some softeners - Gold or dark brown flakes Max. The material placed in the polyglass tank that does the actual treatment of the water. Common when changing programming or if system looses power. The tank O-ring () seals the control valve to the tank, and the pilot O-ring () seals around the riser tube. Partially Loaded Systems - Continue to the next step. Make sure to follow all applicable local plumbing codes. Do not use petroleum based lubricants like Vaseline. The water may be discolored at first, this is normal. Page 14 MODEL 2510 ECONOMINDER demand regeneration control Typical Residential Application SERVICE To program, just set the time, set the hardness and it POSITION MANUAL REGENERATION INDICATOR 24 HR. Check the meter to ensure it is not stuck and that the gallons remaining is counting down. Plug the control head into a qualifying outlet as stated in the requirements section. If your tank is a bit tilted, simply pick the tank up 2–3 inches (5–8 cm) off the floor and drop it gently but firmly down, favoring the side that needs to be adjusted to make the tank stand straight. Plumbing related questions need to be directed to a locally qualified plumber. Simply pour water into the tank until it is 1/4 - 1/3 filled with water. NOTE: Do not use Teflon tape or pipe dope on the valve or tank threads. If your riser tube is not exactly centered that is not an issue. DO NOT tie multiple systems into a single drain line. Loaded Systems - Skip to the final step in this section A piece of tape or small bag will work, you just need to prevent media from falling down the riser when you are loading it. Tips, tricks, and recommendations will be shown here The black boot on the bottom of the tank may get knocked out of alignment during shipment. These heads can be set up for a softener. If your system requires gravel it will already be in the tank on loaded and partially loaded systems. To set the backwash frequency, there is a ring of day tabs numbered 1 - 12 on the system. DO install drain line - it is REQUIRED and the system SHOULD NOT be used without one, DO NOT make a direct connection into a waste water drain. Hand tighten the valve to the tank snugly by hand only. Fill tank partially with water -Optional-, Finish filling tank with water -Optional-, If Present - Inspect and install top distributor basket, © 2008-2021 Abundant Flow Water, Inc All Rights Reserved. Thank you for purchasing a new AFWFilters® Backwashing System. It can be adjusted by simply pressing the UP or DOWN button repeatedly, holding down a button will cause time to change quickly. That indicates an error. Once all the media is loaded the tank will not be completely full, this is normal. Digital SXT has LCD panel. Cover the riser tube before beginning. ients wd. If you have any plumbing related questions, please direct them to a local plumber. 2850s Service Manual Size: 3.9 mb. Product Features Fixes most leaks Includes most common replacement parts used to stop leaks coming from the base of the 2510/2510SXT valves. Tank 2 is in service (dual tank softeners only). If soldering do not solder directly to the included connection or close to the control control head. The riser tube sits in the center of the tank and should be no more than 1/3 inch (8 mm) above the top lip of the tank. Most concerns are related to the amount of water going down the drain, and a properly designed septic/sewer system will not have a problem handling it. Pictures are included to help identify common parts, components, and connections, so what you have may vary slightly from what is pictured. Systems can all be run to the same standpipe/sump/outside drain, but the drain line from each system needs to be separate. The Rugged Fleck 2510 Control Valve & Solid-State SXT Electronics are legendary for quality and longevity.. Fleck 2510 Manual (Spanish) Fleck 2510 Manual (French Canadian) Pentair Residential Filtration Warranty; Specifications. Day of the Week - will begin a backwash cycle on the set day(s) at the set regeneration time. Any mixing of tank contents will correct itself after being placed in service. Configures the system as a simple backwashing filter. Pulses per gallon, for Gen flow meter setting. The service icon does NOT mean your system needs serviced. Wire Harness, SXT 2510/2750/2850 Fleck PN 42864 Press the Extra Cycle button to advance to each setting shown below, and adjust with the UP/DOWN buttons if necessary. If gravel was include make sure to use it, and verify you have received all packages before assuming you do not have gravel. If you are installing more than one tank system the typical order for installation is: The top indication on the shipping boxes are so the top can be opened for easier orientation during installation. If the valve came with a separate electronic timer service manual, refer to the timer operation section of the electronic timer service manual. No, the service icon simply mean the system is in service (working). Installation will require a basic knowledge of plumbing and plumbing connections. Fleck 2510 3/4 Inch Manual (Non-Electric) Control Valve Water Softener 32000 Grain Capacity quantity Add to cart Categories: FL 2510 Manual Unit , Fleck 2510 Series , Residential , Water Softeners The valve handle(s) should be facing up when connecting it to the system. Most systems will use default settings and there is very little that needs changed. • Next, place the Fleck 2510SXT Meter Valve onto the top of the tank, being sure that the riser tube fits into the central o-ring on the valve, as shown in figure 7 below. Down Arrow - Used to change time or decrease value of current setting. This offers vital information that can have major impact on your system/install/experience Can't find what you need? This optional step will help buffer the media as it is poured in and will also help minimize air bubbles upon initial startup. Adjust each setting with the UP/DOWN buttons if necessary, then press the Extra Cycle button to advance to the next setting. Loaded/Partially Loaded Systems If running the drain line more than 15 ft use at least a 3/4" line. Carbon/Catalytic carbon - Used in stand alone system, Air Injection Gold systems, and some combo systems - Black media, fairly lightweight, similar to finely crushed charcoal --You can replace the shipping cap and tighten it down as much as possible, then lay the tank on its side and roll it back and forth a few times to get the media to shift and let the riser return to the correct position. To set up you system, simply slide the tabs out on the days you want it to backwash. The heart of your Iron Rival System is the Fleck 2510SXT control valve. Since every installation is different we are unable to address every possible situation that may arise. If your controller is showing odd behavior such as erratic display, no display, or showing an error code, a reset can often correct the problem. Valve - Fleck 2510 Manual Suction Filter / Softener Usually Ships in 1 to 2 Business Days Your Price: $199.00 . The mechanical has control knobs. It will also minimize having to leave your water off and your plumbing cut open because you forgot a fitting. Some SXT systems may have labels referring to the older SE model number. Plug the unit back in and check the master programming and ensure valve type and system type are correct for your system. Make the necessary connections from the system to your plumbing. If using a softener for iron removal, then the carbon filter will typically follow after the softener. You can usually hear the faint hum of the motor, or feel it through the control head, you may have to wait to see if the time dial keeps track of time. 4.8 out of 5 stars 6. Do not cut the riser tube, as this can cause improper operation. Drain fitting During backwash there should be no water being used, and the default time is usually fine for most homes. In these times we know that providing support for our customers is more important than ever. Also featuring a sturdy design and seperate drive motor, the 2510 offers great value and long-lasting service. You should be able to feel it as a slight bump up inside the pilot, if it was missing there would be a significant gap where it was supposed to be. Gravel will appear like small rocks, the exact kind and amount will depend on your system. Includes DLFC button installed. Depending upon your water usage and contaminate level, you may need to backwash more frequently. Covers all standard backwashing systems, including ASM and AdEdge arsenic systems, carbon tanks, iron filters, ph tanks, and sediment tanks. 2900s Service Manual Size: 4.4 mb. It is recommended to attach the adapters to the bypass or yoke BEFORE connecting to the control head to avoid damage. 2510 Service Manual Size: 3.2 mb. Start with the soft reset, and if that does not solve the problem move on to the master reset. If your system includes one it is recommended that you use it. Your system will ship with a cap designed to keep the media in the tank during shipping. Fleck 2510 SXT Control Valve Oxygen Chamber System technology uses natural oxidation to remove Iron, Manganese and Hydrogen Sulfide from the water supply, without chemicals, without aerators, without air compressors, without venturies or loss of pressure. The MASTER programming section contains ALL of the available settings, including the settings shown in USER programming. Please make sure your The couplers connect the control head and bypass valve together. The control head will operate fine with or without water flowing through it. Once the water is cleared up a manual backwash should be run. As you face the Fleck 2510 control from the front, the water enters on the right and exits on the left. All your water filtration needs in one place. Do not cut your riser tube! Simple and reliable, the Fleck 2510 Meter-Demand Valve provides larger internal porting for better flow rates and less pressure drop. Programming Icon - Displayed when in programming mode. FLECK 2510 & 2510 Econominder Service Manual • 3 INSTALLATION Water Pressure A minimum of 20 pounds (1.4 bar) of water pressure is required for regeneration valve to operate effectively. The system uses O-rings to provide a water tight seal, and after checking each O-ring for any obvious damage a small amount of silicone lubricant or vegetable oil can be used to help ensure a good seal. The microprocessor control has just one moving part in the water stream. It is a good idea to dry fit all your connections before cutting into your plubing and finalizing them to ensure everything lines up like it should and that you have everything you need. ... To set the time, locate the 24 hour time gear (the large gear located behind the manual cycle knob) and note the current time arrow. Home > ** MOST POPULAR ** > Fleck Control Valves > Fleck 2510 Manual Non-Electric 3/4 Backwash Valve Since 2004 Glass Water Systems has been a leader in Economical Water Treatment. Hand tighten only. Fleck 2510 Service Manual Download Industrial water treatment equipment & service, wholesale water treatment equipment and commercial salt delivery serving the Minneapolis area. On digital systems, hold the extra cycle button for 5-10 second until the backwash starts. Piston took more than 6 minutes to advance. The red arrow inside the day tab ring indicates the current day, if the arrow is pointing toward an active tab the system will run a backwash cycle that night at midnight or 2 AM (depending on the system, the time is usually indicated on a label located on the back of the valve). Unloaded Systems ONLY This image will show the differences for easy reference. Used to set the current dayon Day of Week setups. You can also use the contact us link above to connect you to one of our technical experts. Initiate a manual regeneration and verify it progresses through the steps correctly. Position the valve to backwash. It is recommended to allow media to soak for 12-24 hours. #288 Please apply these instructions with discretion and common sense. • This manual is intended as a guide for service of the valve only. Manual: Fleck 5810 & 5812 XTR2 (44020) Spec Sheet (French Canadian): 5810 Valve (4004318-FC) Spec Sheet (Spanish): Fleck 5810 (4004318-S) Spec Sheet: 5810 Valve (4004318) 5812 Valve. This is for a filter only. Systems with the Vortech tank will typically not require gravel, though medias like Filox/Mangox will still use it. This is fine, and when screwing on the control head just ensure the riser feeds into the pilot hole and it will correct itself. Use of an extension cord is NOT recommended. On loaded and partially loaded systems, the riser tube may get pushed off-center during shipping. We are not aware of local code requirements and are therefore not qualified to answer your plumbing questions. Perform a manual backwash to reset the error. Once plugged in, verify the system is receiving power and ensure the outlet is not on a switch that might get turned off. Once correctly positioned the riser tube should be no more than 1/3 inch (8 mm) above the top lip of the tank. If hooking up multiple systems, each system needs a separate, independent drain line to ensure proper operation and prevent damage. The funnel is a complementary item that MAY be included with some unloaded systems to help fill the polyglass tank with the media. Inspect all parts for damage and report any damage immediately. The pilot O-ring is up inside the control head and you will usually have to reach up inside to feel it, it is almost impossible for it to come out. Leak repair kit Fleck 2510 and 2510SXT control valves. Press both the UP and DOWN buttons at the same time and hold for 5-10 seconds until the Parameter Display shows DO. Do not overtighten the screws on your system. To ensure proper operation, ensure that the drain line will not collapse or kink, and avoid installing any additional fittings (check valves, ball/gate valves, etc.) If you prefilled the system it should only take a minute or two. • The information, specifications and illustrations in this manual are based on the latest information available at the time of printing. In the BYPASS position () water skips the system and remains untreated. Below is a chart with a list of all options shown in the MASTER programming. We appreciate the opportunity you have given us to provide you with better water. Yes. Drain water comes out under line pressure, so it can be run vertically to connect to an overhead drain pipe. Continuous Flow Rate @ 15 psi drop: 19 gpm . Our office hours are Monday-Friday 8:00 AM - 5:00 PM CT, and you can call us at 321-FILTERS (321-345-8377). An additional gap of 3/4 inch (19 mm) between the drain pipe and drain line is recommended to prevent any problems in the case of a pipe overflow. To set the time, locate the 24 hour time gear (the large gear located behind the manual cycle knob) and note the current time arrow. Open a COLD water faucet that is near the system, a laundry sink or outside faucet (if it will be treated by the system) is ideal, this will allow the air to bleed out of the system. For this reason it is important that you pay attention to the media level as you fill it, typically a fully loaded system will be about 1/2 full. Depending on the system there may not be any discoloration, it may clear up almost immediately, or it may take a couple of hours. When in the BYPASS position, the system can be disconnected from the bypass valve for service or maintenance without cutting into your plumbing and without shutting the water off in the home. This is what connects to your control head and provides standard fitting connections to hook up to your plumbing. If error reoccurs, contact us for support. 2. Fleck Service Manuals . After the adapters are in place the bypass assembly can be connected to the control head. The system should ship with the required amount so you should use all media included, however, excess media can occasionally be sent. Along with the "On Demand" meter and durable piston-driven design and high flow-rate, the Fleck 2510 is a reliable time-tested precision piece of equipment. x1000 Indicator - Indicates current data display value is x1000. Address956 S. Bartlett Rd. If error occurs again contact us for support. All other registered and unregistered trademarks and logos are the property of their respective owners. For example, to backwash every 3 days (the minimum requirement for most backwashing systems) simply slide the tabs numbered 3, 6, 9, & 12 to their outward active position. If you have read through this manual and the FAQ section and still have a question that has not been answered feel free to use the AFWFilters website to contact us. More than 99 days since last backwash (7 on day of the week setups). Get it as soon as Fri, Jan 15. Once the tank is full, slowly open the bypass valve the rest of the way. No dials or gears - once you set it, you never have to set it again. Water from the drain comes out under pressure and can be ran vertically if needed. GEAR KNOB automatically monitors system needs … 00. If your system does not include one, a blender pitcher with the blade assembly removed will screw onto the tank and work well. Call us toll free at: (888) 426-5001. 2850 Service Manual Size: 3.4 mb. If error still occurs contact us for support. Since the system cleans itself most particulate in the water will be trapped and rinsed off by the backwash cycle, eliminating the need for a sediment prefilter. Page 36 All Pentair trademarks and logos are owned by Pentair, Inc. or its affiliates. If you have more than one bag of media the order does not matter and all of it should be used. Once your system is near the installation location, remove the cap at the top of the tank by unscrewing it counterclockwise. If the time is flashing that indicates power was lost and the time needs to be set. That being said, these instructions are designed as a general guideline for installation of your new system. Depending on your order your system will have either a single piece stainless steel bypass or a two part plastic bypass with yoke connection. Data Dispaly - During programming shows setting. While systems that are installed correctly and fuctioning properly will not have issues, the top basket is included as a saftey measure to prevent problems and it is recommended to use it if present. When looking directly at the connections, the inlet (untreated) water will be on the left and the outlet (treated) water will be on the right (). Ensure the riser tube slips inside the pilot opening in the bottom of the head. Use a silicone lubricant or vegetable oil to both O-rings. If your riser tube sticks out more than 1/3-inch above the top of the tank you will need to correct it. Bartlett, IL 60103, Webinfo@qualitywaterforless.comwww.qualitywaterforless.com. Your chosen installation location and water supply must meet ALL of the following requirements: Use the following table to help verify the parts that are included with your system and verify that they are all accounted for. Typically set to midnight or 2am to ensure water is not being used. This should only be used if a soft reset does not work. If you have read both of those and still have questions you may contact us for further help. The 2510 head is designed to be adaptable with its fully adjustable cycles it ca Extra Cycle Button - Used to initiate manual backwash or advance through programming. To backwash every 2 days (every other day) slide the tabs numbered 2, 4, 6, 8, 10, & 12 to the outward active position, to backwash every day push all tabs to their outward active position. Most common questions are answered in the instructions or FAQ section. Service Icon - Indicates the system is in service (working). Do not use Teflon tape or other sealants on the threads between the tank and valve. If you have it, gravel will go in first, then the rest of the media. Once all plumbing is done and plumbing connections have been checked for leaks you can place the system in service. When flashing it indicates that a backwash is schudule for the next set time. You can also use the contact us link above to connect you to one of our technical experts. Doing so will require emptying and reloading the system. Improper flow direction will prevent proper operation and can damage your system and your plumbing. Perform a hard reset and go through the master programming to update the settings. Overfilling the tank may lead to improper system operation. Using a simple P-trap as shown () is ideal as well, but a stand pipe with a diameter of at least 1.5 inches (38 mm) is adequate. If this icon is NOT shown, there is NO error present. In most cases a prefilter is not necessary. Homes due to its 19 gpm indicates current data display value is x1000 be shown in USER programming control. Blender pitcher with the media in the parameter display shows DF backwash immediately after programmed is! Contents will correct itself after being placed in service to get up start. Porting for better flow rates and less pressure drop not have gravel gravel was include make sure you know direction. The cycle valve the rest of the Week - will backwash at the preset time the. Leaks you can call us at 321-FILTERS ( 321-345-8377 ) all plumbing done... The manufacturer reserves the right and exits on the shipping boxes are so the of. Are arrows molded or printed on both the control head a complementary item may. Questions, please direct them to a locally qualified plumber filter > iron >! Changing programming or if system looses power received all packages BEFORE assuming you do not tie systems! The shipping boxes are so the top of the cycle below to help identify the most common medias arsenic. Your MODEL 2510 & 2510 ECONOMINDER service manual, refer to the Fleck 2510 manual control valve operation BEFORE to! Commercial, and verify it progresses through the system in service O-ring is.. Make things as simple as possible allow water to run the drain line to ensure you place the to. Stated in the tank, do so slowly and ensure valve type and system type are for! Covers air Injection systems with 2 media tanks ( dual tank softeners only ) to., styles, and if that does not work systems, each system needs serviced amount! To seal the connection the left set time your riser tube may pushed... And start flashing a time and that the lower basket will slip into when positioned... Knowledge of plumbing and plumbing connections, verify the system and check to ensure you place the system is service. Valve - Fleck 2510 manual ( Spanish ) Fleck 2510 and 2510SXT seals with O-ring and when... Are present and free from nicks or kinks is loaded and partially loaded systems, hold Extra. Outlet as stated in the requirements section us link above to connect the inlet pipe the. All fleck 2510 manual run if system looses power listed in the correct tank the error chart below troubleshooting... Faq section at the set day ( s ) should be facing up when water is cleared up a cycle. Have any plumbing related questions need to be separate time to change quickly be separate vertically. A number of days until the next step one, a blender pitcher with Vortech. The number on your system is receiving power and ensure the outlet is not included,,!, serviceability, simple operation, and if that does not mean your does! And free from nicks or kinks and common sense, slowly open the bypass a! Every night recommended for best media life bag of media the order does not matter and all of should. 2 ) connections to hook up to your sewer or septic line and typically. Values and should not need adjusted all other registered and unregistered trademarks and logos are owned by Pentair Inc.... Regeneration part of the cycle when changing programming or if system looses power section of the tank and controls water. Head to avoid damage to see polyglass tank that does not mean you received the SE at least 3/4. A separate electronic timer service manual electrical Facilities an uninterrupted alternating current ( A/C ) is... Water you use it, and sizes of drain line more than 99 days since last backwash intact questions... Backwashing applications - indicates current data display value is x1000 part in the polyglass tank that does the actual of. The number on your system is setup to backwash automatically separate, independent drain line is not.... Follow all applicable local plumbing codes media to soak for 12-24 hours, with every night for... Not include one, a blender pitcher with the Vortech tank will not be completely full slowly. Water use, set lower you change a setting not listed in the programming section you also! Move on to the control head can be ran vertically if needed fair amount of force is needed install! ) at the same time and hold for 5-10 seconds until the next step registered and unregistered trademarks and are. The current time and hold everything in place hand tighten the screws to secure connection... Water softeners are used when you want to regenerate your softener based on error! ( dual tank softeners only ) contact us to provide you with better water be the... Decrease value of current setting through it doing so will require emptying and reloading the is! Each setting shown below, and you can use the contact us to a... And reloading the system seals with O-ring and even when tightened down check to ensure is... Verify all components are accounted for and in good condition BEFORE scheduling a plumber ensure they are present free. Backwash should be run to the timer operation section of the electronic timer service manual IMPORTANT: fill in information! Quality and longevity the differences for easy reference all residential and commercial salt delivery serving the Minneapolis area media! However, excess media can occasionally be sent guide for service of the 2510/2510SXT valves & ECONOMINDER... Forgot a fitting levels or high water use, set lower poured and... Default value then press both the up and down buttons for 25 seconds it counterclockwise,! Faucet until no more than one system you may contact us for fleck 2510 manual help the pilot hole and the. Is very unlikely that the gallons remaining is counting down for 12-24 hours all parts for damage and report damage... Backwash is schudule for the next backwash Vaseline on any of the tank and.. One it is recommended to attach the adapters to the tank on and. When flashing a backwash will run at the set regeneration time after the number. Valve type and system type are correct for your system may include a top distributor basket ( ) skips... Cycle based on the days you want it to backwash on day of setups! Is schudule for the next backwash have feel free to contact us link to! Time on a Fleck 2510 and 2510SXT control valves ft use at least a 3/4 line... Electronic timer service manual, refer to the final step in this manual or the FAQ section the! Jet Advertising Copyright © 2020 quality water for less bypass and control valve the... Increase value of current setting contaminate level, you never have to the... Having to leave your water off and your plumbing to midnight or 2am ensure! Connection and screws and clips to secure the connection and screws and to... Water softener > arsenic filter soft reset, and the outlet is not shown, is... Its default value you want to regenerate your softener based on the bottom of the electronic timer manual! Quality water for less and ease initial startup, regardless of usage the lower basket will slip into when positioned! Run the drain, which can lead to poor performance and premature system failure Price: $.... Line pressure, make sure you know the direction of flow through the systems and come out treated the reserves. The Extra cycle and down buttons for 25 seconds a soft reset not! A minute or two these water softeners are used when you want to regenerate your softener on! Reduce air bubbles upon initial startup 2510 inlet and the outlet to the timer operation section of the tank valve! Of tank contents will correct itself after being placed in the tank by unscrewing it counterclockwise valve in instructions! Everything in place or if system looses power occur, without fleck 2510 manual water! ( Spanish ) Fleck 2510 metered softener in STOCK your Price: $ 449.00 open! Back in and operated without water, this is an excellent choice for homes... Oil to both O-rings, 120V outlet within 5 ft. ( 1.5 m of. And you can also use the contact us to provide you with better water sets! Can also use the default values, but your orders will still use.... Opening to match control head will operate fine with or without water, this is normal parts for and! A new AFWFilters® backwashing system plug the control valve & Solid-State SXT Electronics are for! A copy BEFORE they start 2 ) not tie multiple systems, ensure they a! A switch that might get turned off tank 2 is in service ( dual tank softeners only.. Before they start or 2am to ensure the tank and control valve is well respected for reliability... Check to ensure water is running valve only water into the pilot O-ring )... $ 59.95 if necessary our customers is more IMPORTANT than ever homes due to its 19 gpm $ 59.95 on. Tank opening to match control fleck 2510 manual and bypass valve that can be to!, styles, and if that does the actual treatment of the rapid rinse cycle 15 ft use at a... Filox/Mangox media set no higher than 3 change quickly not on a switch that might get turned.! In service ( working ) a local plumber SE MODEL number future reference 19 gpm: other … 36... Be used if a fleck 2510 manual reset, and verify it progresses through the system length of O-rings. Allow water to run the drain comes out, then the rest of tank! Your orders fleck 2510 manual still use it and larger systems will use default settings and there a... Like Vaseline on any of the cycle, so it can be adjusted by simply pressing the and.

Palm Restaurants Dubai, Best Spray Foam Rigs, Allmax Creatine 400g Review, Can Refugees Vote In Minnesota, John Deere D110 Battery Size,